How to perform: Fuel Rail Pump Solenoid Test using Caterpillar ET Software?
Purpose:
The Fuel Rail Pump Solenoid Test function can be used to verify the
operation of the fuel rail pump solenoid. This test provides a method
for determining whether or not an open circuit or short circuit is
present.
-Connect CAT ET Software, Read More: How to Connecting Caterpillar ET Software to the ECM
-Open Menu: “Diagnostic”- “Diagnostic Test” – “Fuel Rail Pump Solenoid Test”
-Click on “Power All” or “Start” and wait the process until completed (Mode: powered)
-On tab “Test Results” is Not OK (*Short), indicates that the Fuel Rail Pump Solenoid is damaged/shorted.
NOTE:
-This test identifies an open circuit or a short circuit for the Fuel
Rail Pump Solenoid. The test activates the solenoid while the engine is
not running. A good solenoid will create an audible click when the
solenoid is activated. CAT ET indicates the status of the solenoid as
“OK”, “Not OK (Open)”, or “Not OK (Short)”.
Test Operation:
During the Fuel Rail Pump Solenoid Test, the ECM pulses 105-volt to the
solenoid. The pulses are sent at the proper time and for the correct
duration for a given engine load and speed. The ECM monitors the current
flow through the circuit for each solenoid. If the current flow is too
high or too low, the ECM activates one of the following diagnostic
codes:
1779-5 Fuel Rail Pump #1 Output Current Below Normal
1779-6 Fuel Rail Pump #1 Output Current Above Normal
1780-5 Fuel Rail Pump #2 Output Current Below Normal
1780-6 Fuel Rail Pump #2 Output Current Above Normal